Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Journal of Interventional Radiology ; (12): 447-450, 2017.
Article in Chinese | WPRIM | ID: wpr-619314

ABSTRACT

Objective To discuss the clinical value of intravascular ultrasound (IVUS) in treatinginternal carotid arteries occlusion.Methods The patient was diagnosed with internal carotid artery occlusionthat was confirmed by CTA.Cerebral perfusion imaging showed that low perfusion area was consistent withischemic symptoms.Guided by IVUS,percutaneous transluminal angioplasty (PTA) was performed.By usingmicro-catheter coaxial technology,the micro guide wire was inserted in the carotid artery until it passedthrough the obstructed segment;After IVUS examination proved that the micro guide wire was in the truelumen of carotid artery,angiography through micro-catheter was carried out to confirm that the distal arterywas unobstructed;after adjusting the device position the embolism protector was placed.The plaque andlumen condition were assessed with IVUS,which was reevaluated after pre-expansion of balloon.After normaldirection blood flow was regained,the plaque stability was assessed with IVUS virtual organization sequence.Simple balloon dilatation therapy was adopted as the fibrous cap of plaque was in stable condition and thelumen stenosis rate was <40%.Results After balloon dilatation,the obstructed artery was reopened and theblood flow regained normal direction.IVUS examination showed that during the whole operation process thefibrous cap of plaque at the narrowed segment remained in stable condition,the lumen stenosis rate was <40%.Cerebral perfusion imaging revealed that after the treatment the low perfusion state was markedlyimproved.Conclusion IVUS plays an important guiding role in performing PTA for internal carotid arteryocclusion.This technique can increase the success rate of vascular recanalization and reduce the incidence ofcomplications.

2.
Chinese Journal of Radiology ; (12): 50-53, 2009.
Article in Chinese | WPRIM | ID: wpr-396629

ABSTRACT

Objective To evaluate the diagnostic value of multi-slice three-dimensional computed tomographic angiography(MS 3D-CTA)for vertebrobasilar dolichoectasia(VBD).Methods MS 3D-CTA of 10 patients with VBD were retrospectively analysed.Source images were got by GE Lightspeed pro scanner.Volume rendering(VR)and maximum intensity project (MIP) were adopted to reconstruct 3D images in all cases.Twenty patients were selected as the control group by suspected cerebra[vascular diseases and underwent MS 3D-CTA at the same period.Enumeration data between the patient group and the control group was assessed by Wilcoxon.test.Results There were 2 types of 10 cases with VBD,including simple type(n=4)and saddle type(n=6).Compared with the control group of the length of the basilar artery(B 1,25.60 mm),the deviant degree(Bc,1.20 mm),the height(Bh,1.90 am),the length of the vertebral artery (V1,17.55 mm),the deviant degree(Vc,2.05 mm),and the diameter of BA and/or VA (Bw/Vw,3.05 mm),there is significant difference in the B1 30.20 mm,Bc 7.10 mm,Bh 8.80 mm,V1 23.00 mm,Vc 5.95 mm,and Bw/Vw 5.05 mm(P<0.01,all).Conclusion The clinical performances of VBD is different,MS 3D-CTA is a very effective method for the diagnosis of VBD.

3.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 1650-1651,插2, 2008.
Article in Chinese | WPRIM | ID: wpr-597368

ABSTRACT

Objective To evaluate the value of spiral CT volume reconstruetion(VR) technique in high complex anal fistula fistulography. Methods To analyze retrospectively internal openings and secondary tracts of 35 eases with high complex anal fistula verified by operation and follow-up above 3 months with VR,and compared with operation and outcome of follow-up. Results In 35 eases with high complex anal fistula, for detection of the presence of internal openings ,VR has a sensitivity of 72.7% ,a specificity of 100% ,a accuracy of 74.3% ,a positive predictive value of 100% ,and a negative predictive value of 18.1%. Secondary tracts have a sensitivity of 93.8% ,a specificity of 100.0% ,a accuracy of 94.6% ,a positive predictive value of 100.0% ,and a negative predictive value of 72.7%. Conclusion VR can demonstrate the 3D shape of fistula and is reliable in the diagnosis of internal openings and sec-ondary ducts, and is very valuable in the analysis of high complex anal fistula fistulography.

SELECTION OF CITATIONS
SEARCH DETAIL